Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1202 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Expansion Interface Local Looparound (#240)
This test is nondestructive. The EI local loop around is similar to the Lightwave Transceiver 
Looparound test (#242). A test tone is received by the EI being tested, but is not transmitted out 
to the fiber interface before being looped back. The loop back is internal to the circuit pack. 
Thus, this test does not interfere with the normal fiber data stream.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 
131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check 
for hyperactivity (error 1538). If hyperactive, use reset board 
location
.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 410: Test #238 Expansion Interface Fiber Out-of-Frame Query Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2
Table 411: Test #240 Expansion Interface Local Looparound 
Error 
Code
Test 
Result
Description / Recommendation
1
ABRT
Could not allocate time slot on TDM Bus A. Loop back passed on TDM 
Bus B.
1. If there is no reason to doubt that the EI circuit pack can transfer data 
to or from a TDM Bus, then since the test passed on one bus, assume 
that the test passes on the other bus.
2. If this test continues to abort with the same error, rerun test at 
1-minute intervals up to 3 times.
3. If the test still does not pass on the other TDM Bus, follow the 
procedure for ABORT Error Code 3.
 1 of 4