EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1209
 
2000
ABRT
Response to the test request was not received within the allowable 
time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The test tone was not detected correctly in either direction.
1. Run the test for the active Tone-Clocks on the PNs for which the 
EI circuit pack under test provides a link. This will determine 
whether dial tone is being supplied.
 in 
 in Maintenance Procedures (03-300192).
1 or 2
FAIL
The test tone was detected correctly in one direction, but not the 
opposite direction.
1. Test for the active Tone-Clocks on the PNs for which the defective 
EI board provides a link. This determines if the dial tone is 
supplied.
 in 
 in Maintenance Procedures (03-300192).
Center Stage: These failure codes are possible on a Center Stage 
Switch configuration only when there is just one other PN available for 
looping back the test tone.
 in 
 in Maintenance Procedures (03-300192).
Table 412: Test #241 Expansion Interface 2-Way Transmission Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 5