Table 415: Test #336 Expansion Interface Reset Test 
Error 
Code
Test 
Result
Description / Recommendation
4
ABRT
Could not reset the PN EI circuit pack over the optical fiber since the 
neighbor EI circuit pack or SNI circuit pack is not recognized by software 
(inserted).
1. Insert neighbor EI circuit pack or SNI circuit pack and perform reset 
again.
1015
ABRT
The system will not allow this test to be run because the EI circuit pack 
has not been busied out.
1. Busyout the EI circuit pack. Enter reset board location.
2. Retry the command.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
2100
ABRT
Could not allocate the necessary system resources to run this test.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
The EI did not successfully reset.
1. If the EI circuit pack is in the PN, the PN’s Maintenance board may be 
holding the EI circuit pack reset. Attempt to rectify this condition by 
executing test maint P long on the Maintenance board in the 
same PN.
2. If step 1 was not successful in releasing the EI circuit pack, 
temporarily remove the PN’s Maintenance circuit pack.
3. Repeat reset board location.
4. If reset continues to fail, replace circuit pack.
5. Insert PN’s Maintenance circuit pack if it was removed.
2
FAIL
The EI circuit pack was successfully reset, but it did not begin running 
after the reset.
1. If the EI circuit pack is in the PN, temporarily remove the PN’s 
Maintenance circuit pack.
2. Use reset board location.
3. Reinsert the PN’s Maintenance circuit pack if it was removed.
 1 of 3