S8710 Alarms
Issue 1 June 2005
123
 
S8710 server BIOS error messages 
The S8710 server BIOS error messages are listed and interpreted in 
Threshold
Temperature: above for which an alarm is generated, in degrees Fahrenheit 
and Celsius.
Table 36: S8710 Temperature and voltage report (continued)
Field 
Description
 2 of 2
Table 37: S8710 BIOS error messages
Error
Code
Description
Audible
Beeps
Possible Problem
Possible Action
207
Memory configuration 
warning; DIMM in DIMM 
Socket X is not 4 bytes 
wide (32 bits) and only 
supports standard ECC.
None
Installed DIMMs are 
8 bytes wide (64 
bits).
Escalate; replace 
the media server
209
Online spare memory 
configuration; spare bank 
is invalid. Mixing of DIMMs 
with 4 and 8 byte widths is 
not allowed in this mode.
One 
long and 
one 
short
Installed DIMMs for 
online spare bank 
are of a different 
primary width than 
the DIMMs in other 
banks.
Escalate; replace 
the media server
NA
A mixture of 533-MHz and 
400-MHz front side bus 
speed processors 
detected. All processors 
must have the same front 
side bus speed. System 
halted.
One 
long and 
one 
short
Wrong processors; 
Processors have 
different front side 
bus speeds.
Escalate; replace 
the media server
NA
Media server only supports 
400-MHz front side bus 
speed processors. One or 
more 533-MHz front side 
bus speed processors 
have been initialized at 400 
MHz.
One 
long and 
one 
short
Wrong processors; 
Media server does 
not support a front 
side bus speed of 
533 MHz.
Escalate; replace 
the media server