Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1232 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2
FAIL
The EI circuit pack was successfully reset, but it did not begin running after 
the reset.
1. If the EI circuit pack is in the PN, temporarily remove the PN’s 
Maintenance circuit pack.
2. Repeat reset board PCSS.
3. Re-insert the PN’s Maintenance circuit pack if it was removed.
3
FAIL
The reset over the optical fiber failed.
1. Execute test board PCSS on the PN neighbor EI circuit pack 
located on the opposite end of the fiber from this EI circuit pack. If Test 
#238 does not pass, follow the maintenance procedure associated with 
this test result. Then perform the reset again.
2. If the EI circuit pack is in the PN, temporarily remove the PN’s 
Maintenance circuit pack.
3. Repeat reset board PCSS.
4. Reinsert PN’s Maintenance circuit pack if it was removed.
5. Follow the procedure described in the “Relationship Between 
Expansion Interface and Tone-Clock Circuit Packs” section if the 
symptoms match those described there.
6. Check the Error Log for the PN Tone-Clock errors that were resolved 
about the same time when the PN went down. These PN Tone-Clock 
errors may have been resolved because the PN went down. When 
there is no Tone-Clock generating the system clock on a PN, then an 
EI circuit pack can only be reset once. Every subsequent reset attempt 
fails. It is also possible that the system itself may have already tried to 
reset the EI circuit pack. See 
page 2327 for recommended maintenance strategy for Tone-Clock 
problems.
3
FAIL
(
cont’d
)
7. If the reset still fails, execute the Manual Loop Back Procedure on the 
opposite PN EI circuit pack. This procedure is described in the section 
preceding the Hardware Error Log Entries and Test to Clear Values 
table for this MO. If the EI circuit pack and the lightwave transceiver are 
healthy, the problem must lie with the EI circuit pack and its lightwave 
transceiver on the PN end of the fiber or with the fiber itself. Test the 
PN EI circuit pack with the manual loop back procedure and investigate 
the test results.
Table 417: Test #224 Expansion Interface Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 5