Avaya 03-300430 User Manual

Page of 2574
EXT-DEV (External device alarm)
Issue 1 June 2005
1241
 
System technician-demanded test:
Descriptions and error codes
Alarm query test 
(#120)
The external device alarm test requests the status of the external device alarm from a 
maintenance circuit pack and reports the results. The test has no affect on the external device 
itself. The test environment command will report an error against Test #120 if there is a 
short on one or both of the pairs of leads connecting the external device. 
!
CAUTION:
CAUTION:
Alarms can be generated on adjunct equipment, sent to the Avaya system, and 
recorded and reported as "external alarms". The adjunct equipment must provide 
an isolated contact closure across the alarm leads provided by the Avaya system. 
The contact must be rated at a minimum of 60 V DC, with a current carrying 
capacity of 5 mA minimum. 
Order of investigation
Short test 
sequence
Long test 
sequence
D/ND
Alarm query test (#120) X
X
Nondestructive
Table 423: Test #120 Alarm query 
Error 
code
Test 
result
Description and Recommendation
1000
ABRT
This is an internal system error.
1. Repeat the command at one-minute intervals 1 to 3 times.
1035
ABRT
The port network is not available. 
1. Use status port-network to verify that the network is not up.
2. Look for alarms against EXP-PN, EXP-INT, PK-INT, etc.
3. Use diagnostic procedures for those MOs to clear the problem.
2000
ABRT
A response to the test request was not received within the time allowed.
1. Repeat the command at one-minute intervals 1 to 3 times.
 1 of 2