EXT-DEV ADMIN? Y (External Device Alarm)
Issue 1 June 2005
1249
 
Any
FAIL
The External Device Alarm has been activated by the external device.
1. Clear the major alarm on the external device, and rerun the test.
2. If the test still fails, then disconnect the External Device Alarm Leads 
from the Maintenance circuit pack and rerun the test.
3. If the test still fails, then there is a problem with the analog external 
device alarm port or the Maintenance circuit pack that is reporting the 
alarm. This circuit pack should be replaced. There are failures that can 
occur on the Maintenance circuit pack that will not be detected by their 
respective maintenance, but that will cause many environment tests to 
fail. If many environment tests are failing, the suspect circuit pack 
should be replaced and the test rerun.
PASS
If there is a problem with the external device, but the administered analog 
line external device alarm, or the administered Maintenance circuit pack 
connected to the device reports no alarm, then the External Device may not 
be properly reporting the problems or the External Device may not be 
properly connected to the External Device Alarm Leads.