Avaya 03-300430 User Manual
FIBER-LK (Fiber Link)
Issue 1 June 2005
1257
2031
ABRT
The attempt to send the message to the EI circuit pack, asking it who it’s
neighbor is, was not successful.
neighbor is, was not successful.
1. Run test board location separately for each EI endpoint on this
fiber link, and follow the procedures for this test in
2100
ABRT
System resources required to run this test are not available.
1. Run test board location separately for each EI endpoint on this
fiber link, and follow the procedures in
2500
ABRT
Internal system error
1. Run test board location separately for each EI endpoint on this
fiber link, and follow the procedures in
1033
FAIL
The EI circuit pack under test cannot make contact with opposite end EI or
SNI circuit pack.
SNI circuit pack.
1. Run test board location separately for each EI endpoint on this
fiber link, and follow the procedures in
2027
FAIL
The EI circuit pack has contact with the opposite EI or SNI circuit pack, but
it is the incorrect EI or SNI circuit pack.
it is the incorrect EI or SNI circuit pack.
1. Run test board location separately for each EI endpoint on this
fiber link, and follow the procedures in
PASS
The EI circuit pack(s) have successfully established a link with the
opposite EI or SNI circuit pack.
opposite EI or SNI circuit pack.
1. If status port-network still indicates that this link is down, it is
possible that one or both of the EI and/or SNI circuit packs have been
busied out.
busied out.
2. If the link still does not come up, reset one or both EI and/or SNI circuit
packs on the link.
Table 436: Test #237 Expansion Interface Neighbor Query Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2