FIBER-LK (Fiber Link)
Issue 1 June 2005
1261
 
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABRT
SNI circuit pack responded that it is not able to run the test requested by 
software.
1. Retry the command at 1-minute intervals up to 3 times.
2306
ABRT
A fiber link’s SNI circuit pack is not responding to test requests sent by 
software.
1. Run test led switch-node for the switch node where the SNI 
board(s) reside to verify whether their LEDs light. If not, continue with 
the following steps.
2. If LEDs light on other boards in the same carrier (but not on this board), 
enter test board location l (#760) for the active SNC in this 
carrier. Wait 5 minutes, and try step 1 again. If the board’s LEDs still do 
not light, replace the board. (Replacing an SNI may be service 
interrupting. Refer to the SNI-BD section for the procedure to replace 
an SNI.)
3. If no LEDs light on any board in the same carrier, fix any connectivity 
problems between this carrier and the media server. Use list 
fiber-link
 to determine the fiber connections to this carrier. Check 
the LEDs on every SNI and EI, and fix any fiber problems. Enter 
display errors, and resolve any SYNC, SNI-BD, SNC-BD, 
FIBER-LK, or SNI-PEER error entries.
Table 438: Test #756 SNI Off-Board Destructive Facility Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3