FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 3. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 257, replace the SNI 
being tested. (Replacing an SNI may be service interrupting. Refer to 
the SNI-BD section for the procedure to replace an SNI.) To view 
SNI-PEER errors, use display errors with category PNC-PEER. 
Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 257, replace the 
SNI in slot 3.
104
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 4. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 513, replace the SNI 
being tested. (Replacing an SNI may be service interrupting. Refer to 
the SNI-BD section for the procedure to replace an SNI.) To view 
SNI-PEER errors, use display errors with category PNC-PEER. 
Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 513, replace the SNI 
in slot 4.
Table 440: Test #759 Configuration Audit  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 22