FIBER-LK (Fiber Link)
Issue 1 June 2005
1273
 
118
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 18. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3329, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3329, replace 
the SNI in slot 18.
119
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 19. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3585, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3585, replace 
the SNI in slot 19.
Table 440: Test #759 Configuration Audit  (continued)
Error 
Code
Test 
Result
Description / Recommendation