Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1276 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
140
FAIL
The Endpoint 1 SNI is physically connected to a DS1 converter but is not
administered to be connected to a DS1 converter. Use list
fiber-link to see a fiber link’s endpoints. Either add the DS1 converter
administered to be connected to a DS1 converter. Use list
fiber-link to see a fiber link’s endpoints. Either add the DS1 converter
complex to the fiber that this SNI is associated with:
1. Check for the fiber that this SNI is an endpoint of by checking list
fiber-link.
2. Remove fiber-link for the fiber that this SNI is an endpoint of.
3. Add the fiber back via add fiber-link and administer the DS1
3. Add the fiber back via add fiber-link and administer the DS1
converter complex also. Or, remove the DS1 converter connection and
connect the SNI directly to its administered fiber endpoint by entering
list fiber-link and verifying that the fiber-optic and metallic
connect the SNI directly to its administered fiber endpoint by entering
list fiber-link and verifying that the fiber-optic and metallic
cable connections are installed as administered.
202
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped
SNI in slot 2. Use list fiber-link to see a fiber link’s endpoints.
SNI in slot 2. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the
in
in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to
the SNI-BD section for the procedure to replace an SNI.) To view
SNI-PEER errors, use display errors with category PNC-PEER.
the SNI-BD section for the procedure to replace an SNI.) To view
SNI-PEER errors, use display errors with category PNC-PEER.
Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1, replace the
SNI in slot 2.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation