Avaya 03-300430 User Manual

Page of 2574
Denial Events
128 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Cause Values and their meanings/interpretations   
See 
Denial Events that show Cause Value information (Cause Value, Location Code, and Diagnostic 
Code) in Event Data 2 fields.
Event Data 2 sometimes contains data that represents the Cause Value (CV) (required), Cause 
Value Diagnostic (DIAG) (optional), Location Code (LC) (optional) from the denial event. This 
information (DIAG/LOC/CV) is coded as a 32 bit hexadecimal number, divided into 8-bit fields.
The least significant (right most) two digits are the Cause Value in hexadecimal.
The next two digits to the left are the Location Code (optional) in hexadecimal. See 
The next two digits to the left are the Diagnostic Code (optional) in hexadecimal.
The most significant (left most) two digits are not used.
See 
Interpreting Event Data 2 Cause Value information 
In our example, we will use Denial Event 1178 with Event Data 1 and Event Data 2.
1. Note the information under the Event Data 2 column: 0x429.
0x29 is the Cause Value.
0x4 is the Location Code.
0x00 is the Diagnostic Code (not provided for this denial event).
Table 39: Event Data 2 layout
8 bits
8 bits
8 bits
8 bits
NOT USED
Diagnostic Code 
(DIAG) (optional)
Zero + Location Code in lower 4 bits 
(LOC) (optional)
Cause Value
(CV) (required)
display events denial 
Page   1  of  1
  
                                EVENTS REPORT
Event Event                      Event     Event      First       Last     Evnt
Type  Description                Data 1    Data 2     Occur       Occur     Cnt
1178
Normal Call Clearing
0x64
0x429
01/09/09:53 01/09/09:53  1