Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1282 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
216
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped 
SNI in slot 16. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2817, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 2817, replace 
the SNI in slot 16.
217
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped 
SNI in slot 17. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3073, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3073, replace 
the SNI in slot 17.
Table 440: Test #759 Configuration Audit  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 18 of 22