Avaya 03-300430 User Manual

Page of 2574
FIBER-LK (Fiber Link)
Issue 1 June 2005
1297
 
246
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a fiber out-of-frame 
condition, and a loss-of-signal condition. Also, no lightwave transceiver is 
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The 
connected circuit pack is the other endpoint of the fiber link if no DS1 
converter complex is administered (check via list fiber-link). 
Otherwise, if a DS1 converter complex is administered, the connected 
circuit pack is the DS1 converter circuit pack connected to the SNI 
circuit pack.
2. Perform the 
 in Maintenance Procedures (03-300192) in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
PASS
No problems associated with this test are detected on the SNI.
Table 443: Test #989 SNI Fiber Out of Frame Query  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 9 of 9