Avaya 03-300430 User Manual
FIBER-LK (Fiber Link)
Issue 1 June 2005
1297
246
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a fiber out-of-frame
condition, and a loss-of-signal condition. Also, no lightwave transceiver is
connected to the SNI circuit pack.
condition, and a loss-of-signal condition. Also, no lightwave transceiver is
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
connected circuit pack is the other endpoint of the fiber link if no DS1
converter complex is administered (check via list fiber-link).
converter complex is administered (check via list fiber-link).
Otherwise, if a DS1 converter complex is administered, the connected
circuit pack is the DS1 converter circuit pack connected to the SNI
circuit pack.
circuit pack is the DS1 converter circuit pack connected to the SNI
circuit pack.
2. Perform the
in Maintenance Procedures (03-300192) in Chapter 5.
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
PASS
No problems associated with this test are detected on the SNI.
Table 443: Test #989 SNI Fiber Out of Frame Query (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
9 of 9