Communication Manager Maintenance-Object Repair Procedures
1298 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
FW-DWNLD (Firmware Download)
S8700 | 8710
 / 
S8500
Firmware Download provides the capability to download new firmware to one or more 
programmable circuit packs of the same type residing within the same system. Programmable 
circuit packs have a “P” in their suffix. For example TN799DP is programmable, but TN799C is 
not. This programmable capability reduces the need to physically remove circuit packs and 
return them to Avaya for firmware updates
Error Log Entries and Test to Clear Values
on page 1298 shows the error log 
entries and tests apply to self- and C-LAN distributed downloads, not to IPSI downloads.
MO Name in Alarm Log
Alarm Level
Full Name of MO
FW-DWNLD
MINOR
1
1. MINOR alarms can be down-graded to a WARNING level per local 
instructions by using the set options command.
Firmware Download
Table 444: FW-DWNLD Maintenance Error Log Entries 
Error 
Type
Aux Data
Cause of 
Error
Alarm
Level
On/Off
Board
Test to Clear Value
257 (
) See 
associated 
note
Download 
failure
MIN
OFF
test firmware download 
location
258 (
) See 
associated 
note
Download 
failure
MIN
OFF
test firmware download 
location
259 (
)
See 
associated 
note
Download 
failure
MIN
OFF
test firmware download 
location
513 (
) See 
associated 
note
Download 
failure
MIN
OFF
test firmware download 
location
769 (
) See 
associated 
note
Firmware 
download 
request
MIN
OFF
test firmware download 
location