Avaya 03-300430 User Manual

Page of 2574
GPTD-PT (General-Purpose Tone Detector Port)
Issue 1 June 2005
1309
 
Notes:
a. A Major or a Minor alarm may be logged with this error. A Major alarm is raised when the 
total number of GPTD ports currently in service is less than or equal to 1/2 of the threshold 
number administered via change system-parameters maintenance. Otherwise, a 
Minor alarm is raised. In either case, run the short test sequence on the alarmed GPTD port 
and follow procedures for the individual test results.
b. Error Type 0
run the short test sequence first. If every test passes, run the long test sequence. 
Refer to each appropriate test’s description, and follow its recommended procedures
c. Error Type 257: the GPTD port lost its translation. Testing the GPTD port is sufficient to 
reload its translation. If testing the GPTD port does not clear the error, then replace the Tone 
Detector circuit pack containing the defective GPTD port.
d. Error Type 513: the GPTD port is having problems detecting call-progress tones. If this 
error is logged constantly, replace the Tone Detector circuit pack containing the defective 
GPTD port.
e. Error Type 130: the circuit pack has been removed or has been insane for at least 11 
minutes. To clear the error, reinsert or replace the circuit pack.
Technician-Demand Tests: Descriptions and Error Codes
Investigate tests in the order presented.
130 (
)
None
WRN
ON
test port location sh 
r 2
257 (
)
17666
Tone Detector Audit/
Update (#43)
MAJ 
MIN 
(
ON
test port location r 
3
513 (
) Any
Tone Detection Verification 
(#42)
MAJ 
MIN 
(
ON
test port location r 
3
Table 451: General-Purpose Tone Detector Port (CPTR) Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2
Order of Investigation
Short Test Sequence
Long Test Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Tone Detection Verification test (#42)
X
X
ND
Tone Detector Audit/Update test (#43)
X
X
ND