Communication Manager Maintenance-Object Repair Procedures
1312 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Tone Detector Audit/Update Test (#43)
The GPTD port is refreshed with all time-slot information, and a sanity audit is performed on the 
GPTD port.
Table 453: Test #43 Tone Detector Audit/Update Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
The system was not able to allocate the resources needed for this test.
1. Wait 1 minute and try again.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Hardware audit failed.
1. Run the short test sequence:  test port location short 
repeat 1.
2. If the problem persists, the system is still operating properly but system 
capacity will be reduced. To restore the system performance to normal, 
replace the Tone Detector circuit pack containing the defective GPTD 
port.
PASS
The GPTD port has been successfully refreshed with its translation.