Avaya 03-300430 User Manual

Page of 2574
H323-SGRP (H.323 Signaling Group)
Issue 1 June 2005
1321
 
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3times.
2800
ABRT
No C-LAN in the same region.
1. Verify translations and retest.
2801
ABRT
No IP address defined.
1. Verify translations and retest.
2802
ABRT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
89 
1007
FAIL
PING to the destination failed through this port because the destination was 
down.
1. Verify that at least one destination reachable through this port is “up”. 
Once verified, execute test signaling-group grp# to verify that 
the H.323 Signaling Group Ping test (#1387) passes.
ANY
ABRT
Refer to the CLAN Port PING test in 
for a more detailed description of the reasons for the abort.
 ANY
FAIL
The far-end of the signaling group could not be reached. 
1. Refer to the C-LAN port PING test in 
page 1900 for a more detailed description of the reasons for the failure.
PASS
PING through this port was successful.
Table 457: Test #1387 H.323 Signaling Group Ping Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3