Avaya 03-300430 User Manual

Page of 2574
H323-STN (H.323 IP Station)
Issue 1 June 2005
1327
 
Media Path PING Test (#1374)
This test is nondestructive.
The test selects a Media Processor board. It then requests the local Media Processor to 
execute a PING on the endpoint address. If the PING is successful, the test passes. If the PING 
is not successful, the test fails.
Services can execute the standard ping command using the Media Processor board address 
and endpoint IP address to see the actual round-trip delay.
This test checks the IP network connectivity needed for audio packets to be sent to the 
endpoint.
This nondestructive test runs due to in-line errors, during periodic and schedule maintenance, 
and on demand.
Table 462: Test #1374 Media Path PING Test 
Error 
Code
Test 
Result
Description / Recommendation
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2806
ABRT
No Media Processor board found to use for this test.
ANY
FAIL
The system could not PING the registered endpoint from a Media 
Processor board. This may result in calls with no talk path.
1. If the Registration Status Inquiry test (#1372) fails, follow those 
procedures.
2. Refer to MEDPRO, Test #1378, for a detailed description of the error 
codes.
PASS
PING through this Media Processor is successful.