Avaya 03-300430 User Manual
HYB-LINE (Hybrid Line)
Issue 1 June 2005
1333
1000
ABRT
System resources required to run this test are not available. The port may
be busy with a valid call.
be busy with a valid call.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1001
ABRT
Could not allocate the necessary system resources to run this test. This
could be a failure to seize the port.
could be a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out of service due
to TDM-BUS errors.
under heavy traffic conditions or it may have time slots out of service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004
ABRT
The port was seized by a valid call during the test. The test has been
aborted.
aborted.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
Table 465: Test #6 NPE Crosstalk Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 4