Communication Manager Maintenance-Object Repair Procedures
1336 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call. 
1. Use display port location to determine the station extension 
number of the port. Use status station to determine the service 
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Electronic Power Feed test passed. The message to turn on the power to 
the station was successfully sent to the port.
1. Although this test never actually returns a FAIL result, except for the 
previous Internal system error, it logs an error if the overcurrent case is 
detected by the hardware. Check the Error Log for any entries with 
Error Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds 
after completion of this test, it is safe to assume that the test sensed no 
problems with the power to the station. To verify that the station is 
powered up correctly, run a self-test on the station, if available, and 
check that every feature button is operating.
3. If Error Type 257 appears in the Error Log, this indicates some problem 
with the power to the station. Check for a short in the wiring, a 
damaged jack, a defective voice terminal, or an incorrect type of 
terminal.
Table 466: Test #56 Hybrid Electronic Power Feed Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3