HYB-LINE (Hybrid Line)
Issue 1 June 2005
1343
 
Hybrid Line Remote Digital Looparound
Test (#59)
This test checks the digital control pair from the port circuit to the terminal. The on-board 
microprocessor sends a message to the terminal and checks for a proper return message. This 
test is repeated three times, with two out of the three attempts passing being sufficient for this 
test to pass. This test will run if the station is in service or out of service.
Table 469: Test #59 Hybrid Line Remote Digital Loop-Around Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1
ABRT
A request for a remote station audit aborted even though every internal 
resource was correctly allocated.
1. Look in the error log for Error Type 18 (port busied out) for this port. If 
this Error Type is present, release the port via release port 
location
 or release station extension, and then run the test 
again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call. 
1. Use display port location to determine the station extension 
number of the port. Use status station to determine the service 
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2