Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1346 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Hybrid Line Audits Test (#61)
This is a series of three tests that are classified as audits. These audits will abort if attempted on 
an out-of-service station. The tests are as follows:
Switchhook Audit: This updates the media server’s records according to the circuit packs’ 
records.
Bad Scan Inquiry: An up-link message is sent containing a count generated due to certain 
events relating to the data link’s conditions. This indicates data-transmission problems 
between the Hybrid circuit pack and the voice terminal.
EPF Inquiry: An up-link status message of the Electronic Power Feed is sent. Possible 
conditions are: EPF-on-ok, EPF-off, EPF-no-load, and EPF-on-overcurrent.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Line Lamp Updates completed successfully
1. If complaints still exist, investigate by using other circuit pack tests, and 
by examining the station, wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Enter 
list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout 
board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, dispatch to check to ensure that there is a valid board 
inserted.
Table 470: Test #60 Hybrid Line Lamp Updates Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2