Communication Manager Maintenance-Object Repair Procedures
1348 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Line Audits test passed.
1. Although this test never actually returns a FAIL result (except for the 
previous Internal system error), it can enter Error Types 257 and 513 
into the Error Log. To check for problems that don’t show up in the test 
result, look for these error types in the Error Log.
2. If these errors appear in the Error Log, or if user complaints still exist, 
investigate by using other circuit pack tests, and by examining the 
station, wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Enter 
list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout 
board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, dispatch to check to ensure that there is a valid board 
inserted.
Table 471: Test #61 Hybrid Line Audits Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2