Hybrid Line Ringer Update Test (#62)
In this update, a ‘‘ringer on’’ or a ‘‘ringer off’’ message is sent to the firmware to start and stop 
the ringer on the set.
Table 472: Test #62 Hybrid Line Ringer Update Test 
Error 
Code
Test 
Result
Description / Recommendation
3
ABRT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If 
this Error Type is present, release the port with the release station 
extension
 command, and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may be 
busy with a valid call. 
1. Use display port location to determine the station extension 
number of the port. Use status station to determine the service 
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up 
to 5 times.
1392
ABRT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either display port, (the port is 
a TTI port) or list config, which shows a t for the port.
2. If either list config or display port indicate that the port is not a 
TTI port, escalate the problem. If both commands indicate that the port is 
a TTI port, the abort is correct, and no action is necessary.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Station Ringer Update passed
1. If complaints still exist, investigate using other circuit pack tests on this 
circuit pack, and by examining the terminal, wiring, and connections.