Communication Manager Maintenance-Object Repair Procedures
1350 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Enter 
list config, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout 
board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port. If 
this is not the case, dispatch to check to ensure that there is a valid board 
inserted.
Table 472: Test #62 Hybrid Line Ringer Update Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2