INADS (INADS Link)
Issue 1 June 2005
1351
 
INADS (INADS Link)
S8700 | 8710
 / 
S8500
 / 
S8300
The INADS Link MO represents the software and communications link used by the switch to call 
an alarm receiver. The purpose of the INADS Link MO is to:
Check the communications link between the system and the alarm receiver
Verify that the alarm notification process works correctly
To verify that alarms will be reported to the alarm receiver, either a centralized technician can 
remotely test the process, or an on-site technician can test the connection either during an 
installation or a subsequent service call.
Although the INADS Link MO never alarms, its errors are logged, and these errors are only 
logged by issuing test inads-link.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the following INADS Link test 
description.
System Technician-Demanded Tests:
Descriptions and Error Codes
The test inads-link command is different from other test commands:
There is no long or short option.
Resulting test does not have an associated test number.
When a user enters test inads-link, the system immediately returns either the Command 
successfully completed or Command failed message.
INADS Link Test (No Test Number)
The INADS Link test attempts to call an alarm receiver (in the background) to verify the 
communications link with the alarm receiver. When a user enters test inads-link, the 
system immediately returns either a Command successfully completed or Command 
failed message.
MO Name in Alarm Log
Alarm 
Level
Initial SAT Command to Run
Full Name of MO
INADS
none
test inads-link
INADS Link