Avaya 03-300430 User Manual

Page of 2574
INADS (INADS Link)
Issue 1 June 2005
1353
 
4
0
The alarm receiver did not answer the test call.
1. Verify that the alarm receiver is up and running.
2. Verify the accuracy of the alarm receiver’s phone number and the 
system’s product ID using the Maintenance-Related System 
Parameters
 screen.
3. Enable alarm origination using the Maintenance-Related System 
Parameters screen.
4. Test the SYSAM (System Access Maintenance) by issuing test 
maintenance a | b.
5. Retry the command.
5
0
The alarm receiver’s phone number is not assigned.
1. Assign the alarm receiver’s phone number via the Maintenance-Related 
System Parameters screen.
2. Retry the command.
6
0
The alarm receiver did not return an acknowledgment for the “test inads 
alarm” message.
1. Verify the accuracy of the alarm receiver’s phone number and the 
system’s product ID via the Maintenance-Related System Parameters 
screen.
2. Verify that the alarm receiver is up and running.
3. Retry the command.
7
0
The alarm receiver returned a negative acknowledgment for the TESTING 
INADS LINK message.
1. Verify that the product IDs match in the customer’s switch and the alarm 
receiver’s database. Use the Maintenance-Related System 
Parameters
 screen to identify the product ID of the switch.
2. Rerun the test.
8
0
Internal system error. System received an invalid return code.
9
0
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 473: INADS Link Test Error Log Entries  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3