Communication Manager Maintenance-Object Repair Procedures
1358 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 1: the circuit pack has been removed from the system or is not fully 
administered. The alarm is logged about 15 minutes after the circuit pack has been 
removed, or 11 minutes after the SAKI test (#53) fails.
To be fully administered, an IPMEDPRO circuit pack must meet four conditions:
Have an entry in the circuit pack screen (change circuit-pack)
Have the MedPro IP address administered (change node-names ip)
Be enabled (change ip-interface)
Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are 
NOT met, a MINOR alarm is logged. To resolve the error:
2561 (
)
Ping error 
(#1379)
MIN
OFF 
2817 (
)
Any
Ethernet 
Hardware Query 
test (#1405)
MIN
ON 
3073 (
)
Any
Circuit pack reset 
test (#53)
MIN
ON 
3329 (
)
Any
Duplicate 
network IP 
Address detected
MIN OFF
3585 (
1 or 2
Verify NIC option 
test (#1511)
MIN OFF
 3841(
None
Inconsistent 
downlink 
 3841(
4283
RTCP Monitor 
Server error
3999 (
)
Any
None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each 
appropriate test’s description, and follow its recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on values set in set options.
Table 474: TN2302 IPMEDPRO Circuit Pack Maintenance Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 3 of 3