Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1388 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 488: Test #53 SAKI Sanity Test 
Error 
Code
Test 
Result
Description / Recommendation
None
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1015
ABRT
Port is not out of service.
1. Busy out the circuit pack.
2. Execute command again.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2803
ABRT
Need to disable the IP interface.
1. Use the change ip-interfaces screen to disable the Media 
Resource’s IP interface.
2. Execute the command again.
1
FAIL
The circuit pack failed to reset.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
2
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the short test sequence.
Any
NO 
BOARD
This is normal if the test is being done when (a) the board is not physically 
in the system or (b) the system is booting up. Otherwise, there is some 
inconsistency between the physical configuration and the data kept in the 
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for up to 5 times.