Avaya 03-300430 User Manual

Page of 2574
IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005
1389
 
IP Address Update Test #1371
This test is conditionally destructive.
This test queries the Media Resource for its IP address, subnet mask, and gateway translation 
(IP parameters). If the parameters do not match software translation, maintenance software 
reboots the board.
or:
This test sends the IP Media Resource the IP address, subnet mask, and gateway translation 
(IP parameters). If the parameters do not match software translation, the system reboots the 
board. The board goes through a logical board removal and insertion. 
When this test fails, it is an indication that an illegal change was made and the customer should 
be notified.
Table 489: Test #1371 IP Address Update Test 
Error 
Code
Test 
Result
Description / Recommendation
 ABRT
Internal 
system 
error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2801
ABRT
Unable to find IP address data for this location.
1. Verify that the board is administered.
2807
ABRT
The board is administered, but not enabled on the change 
ip-interfaces form.
FAIL
The IP address, subnet mask, and gateway translation parameters do not 
match Communication Manager translations. The board has been reset.
1. If the problem persists, replace the circuit pack.
 
PASS
Translation data matches.