Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1392 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Board StatusTest (#1402)   
This test is nondestructive. 
This test is run at board insertion. The test queries the embedded software (firmware) 
applications to determine if they are running properly. If the test fails once, an immediate retest 
is automatically done. If the test fails a second time, depending on the specific failure type, a 
minor, alarm is logged and the board will not be placed in service. 
2100
ABRT
The necessary system resources to execute the test could not be 
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2801
ABRT
No IP address defined. Verify IP interfaces translations and retest.
2802
ABRT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
2805
FAIL
The number of pings received did not match the number sent (normally 
one ping sent). This means that no ping responses were received from the 
gateway defined on the ip-interface form for the IP Media Resource.
1. Retry the command at 1-minute intervals up to 3 times.
2807
ABRT
The board is administered but not enabled on the change 
ip-interfaces form.
89 
1007
FAIL
A ping to the destination failed through this port. This failure is because the 
destination is down.
1. Verify that at least one destination is reachable through this port.
2. Once verified, execute test port location to verify that the H.323 
Signaling Group Ping test (#1387) passes.
PASS
Ping through this port is successful.
Table 491: Test #1379 Ping Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2