Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1412 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
AUX Data Descriptions
Examples:
Error Code of 30320 with Aux Data 2 software requested the archangel move to the A-side IPSI 
as a result of a PKT-INT fault class improvement.
Error Code of 31041 with Aux Data 1 indicates a software requested interchange from the 
A-side IPSI to the B-side IPSI leaving the archangel on the IPSI due to a loss of TDM clock.
y
Fault class/stimulus 
causing software 
action
1
EAL fault class
2
PKT-INT fault class
3
TONE-BD fault class (not TDM-CLK)
4
TDM-CLK fault class (loss of clock)
7
Preference migration to A-side IPSI
z
Fault or 
improvement
0
This is an improvement in the previous fault class (y).
1
This is a degradation of the previous fault class (y).
Table 505: Encoding of Error Codes for Software Requested IPSI interchange  (continued)
Field
Variable Name
Value Description
 2 of 2
Table 506: Aux Data Descriptions for Software-Requested Interchange
Aux Data
Description
0
No specific extra information is available
1
An IPSI interchange only took place
2
A control change only took place
3
Both an IPSI interchange and a control change took place