Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1430 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ISDN-PRI D-channel signaling can be combined with a group of B channels in three basic ways:
●
FAS (facility-associated signaling)
●
NFAS (non-facility-associated signaling)
●
Backup NFAS signaling
In a FAS signaling group, the 24
th
port of the TN464 UDS1 Interface circuit pack or MM710 DS1
Interface Media Module carries D-channel signaling for up to 23 B-channel ports on the same
circuit pack or media module.
In an NFAS signaling group, the 24
circuit pack or media module.
In an NFAS signaling group, the 24
th
port of one TN464C or higher suffix UDS1 Interface or
MM710 DS1 Interface Media Module can carry D-channel signaling for B channels on several
other DS1 circuit packs or DS1 Media Modules, as well, including TN767s and TN464Bs. The
24
other DS1 circuit packs or DS1 Media Modules, as well, including TN767s and TN464Bs. The
24
th
port on the other circuit packs or media modules can be used as a B channel. A D channel
in an NFAS group can signal for B channels on a total of 20 DS1 circuit packs or media
modules.
D-channel backup provides increased reliability, which is highly desirable since NFAS permits a
D channel to signal for many more B channels. NFAS allows the administration of a backup D
channel that remains in a standby state until the active D channel goes down. If so, the backup
D Channel takes over and provides signaling for every B channel in the signaling group.
The operation of the entire ISDN-PRI signaling group depends on several other entities:
modules.
D-channel backup provides increased reliability, which is highly desirable since NFAS permits a
D channel to signal for many more B channels. NFAS allows the administration of a backup D
channel that remains in a standby state until the active D channel goes down. If so, the backup
D Channel takes over and provides signaling for every B channel in the signaling group.
The operation of the entire ISDN-PRI signaling group depends on several other entities:
●
S8700 | 8710
/
S8500
/
S8300
: The ISDN-PRI signaling channel ports, the TN464 UDS1
Interface circuit pack or MM710 DS1 Interface Media Module, on which the D channels
reside, and the system link that is carried over the packet bus to the processor.
reside, and the system link that is carried over the packet bus to the processor.
When there are problems with the ISDN-PRI signaling group, also investigate
on page 1799, as appropriate.
Error Log Entries and Test to Clear Values
Table 514: ISDN-PRI Signaling Group Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
)
0
Any
Any
test signaling-group grp#
)
Any
None
257 (
Any
None
test signaling-group grp#
513 (
Any
None
test signaling-group grp#
1 of 2