ISDN-SGR (ISDN-PRI Signaling Group)
Issue 1 June 2005
1437
 
Primary Signaling Link Hardware Check (#636)
The ISDN-PRI Signaling Group D-channel port depends on the health of the TN464C or higher 
suffix UDS1 Interface circuit pack or MM710 DS1 Interface Media Module on which it resides. 
This test will fail if there are problems with either the ISDN-PRI Primary D-channel port or the 
UDS1 circuit pack or MM710 DS1 Media Module. If there are problems with the ISDN-PRI 
Primary Signaling Channel port (ISDN-LNK), also investigate the UDS1 circuit pack 
(UDS1-BD), or MM710 Media Module (MG-DS1).
Table 516: Test #636 Primary Signaling Link Hardware Check 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1700
ABRT
Rollabout video abort. The PRI terminal adapter associated with the 
primary D-channel port is detached from the circuit pack or media module. 
This is a normal abort when the rollabout video feature is enabled. To 
complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter, or
2. Enter change ds1 location to disable rollabout video on the 
board, and set the Alarm when PRI Endpoint Detached field to y
8
FAIL
There is a problem with the UDS1 TN464C or higher suffix circuit pack or 
the MM710 DS1 Interface Media Module, or the ISDN-PRI Signaling 
Channel (D channel). No ISDN trunk or PRI endpoint calls can be made 
until the problem is resolved.
1. Consult the procedures for the UDS1 TN464C or higher suffix circuit 
pack (UDS1-BD), or the MM710 DS1 Interface Media Module 
(MG-DS1), and the ISDN-PRI Signaling Channel (ISDN-LNK).
PASS
The basic physical connectivity of the primary D channel is intact and 
functional. One might try this test repeatedly to ensure the link is up and to 
uncover any transitory problems.
 1 of 2