Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1442 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
4
FAIL
There is a problem with the Processor Interface Link. No DS1 ISDN Trunk 
(B-channel) or Wideband PRI Endpoint calls can be made until the problem 
is resolved.
1. Display the Communication-Interface Links Form via display 
communication-interface to determine which link is down (find the 
one that matches the DS1 Interface circuit pack on which this ISDN-PRI 
Signaling Link Port resides) and then refer to 
8
FAIL
There is a problem with the TN464C or higher suffix UDS1 Interface circuit 
pack or the MM710 DS1 Interface Media Module, or the ISDN-PRI 
Secondary Signaling Channel (D channel). No ISDN trunk or PRI endpoint 
calls can be made until the problem is resolved.
1. Consult the procedures for the UDS1 TN464C or higher suffix circuit 
pack (UDS1-BD), (DS1-BD), or the MM710 DS1 Interface Media Module 
(MG-DS1), and the ISDN-PRI Signaling Channel (ISDN-LNK).
PASS
The basic physical connectivity of the Signaling Group’s Secondary D channel 
is intact and functional. Try this test repeatedly to ensure the link is up and to 
uncover any transitory problems.
Any
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute add ds1 location 
to administer the circuit pack or media module interface if it is not already 
administered.
If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the board is 
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then enter busyout 
board location.
Enter reset board location.
Enter release location board.
Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 518: Test #639 Secondary Signaling Link Hardware Check (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2