Communication Manager Maintenance-Object Repair Procedures
1452 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
maint/FE
WRN
Signaling channel has 
been down for over 90 
sec.
Consult ISDN-SGRP and/or 
ISDN-LNK. Far-end signaling 
channel may be busied out, or the 
far-end switch may currently be 
restarting.
WRN
Repeated failure of far 
end to respond to 
messages.
Maintenance software will 
periodically try to resend 
messages. You can speed the 
process with test trunk grp#/
mem# and/or test 
signaling-group sig-grp#.
WRN
The far-end trunk is 
being tested.
Check status of the far-end switch. 
Wait for testing to finish.
in-service
None
Normal operating state
1. ISDN-TRK alarms; alarms against other objects may also be present.
Table 520: Service States (continued)
Service State
Alarm
1
Possible Cause
Possible Solution
 2 of 2
Table 521: DS1 ISDN Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
Any
Any
Any
test port location
Any
None
test port location
15 (
)
Any
Audit and Update Test 
(#36)
18
0
busyout trunk 
grp#/mem#
release trunk grp#/mem#
19 (
0
None
129 (
None
WRN
OFF
test port location
130 (
None
WRN
ON
test port location
257 (
Any
None
test port location
 1 of 2