ISDN-TRK (DS1 ISDN Trunk)
Issue 1 June 2005
1461
 
Signaling Link State Check Test (#255)
The DS1 ISDN Trunk depends on the health of the appropriate TN464C or later UDS1 Interface 
circuit pack, TN767 DS1 interface circuit pack, or MM710 DS1 Interface Media Module for 
proper operation. It also depends on the ISDN-PRI D channel (ISDN-LNK) trunk. This test 
checks the status of those critical elements.
Any
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute add ds1 
location command to administer the MM710 interface if it is not already 
administered.
If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the board is 
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then enter 
busyout board location.
Enter reset board location.
Enter release board location.
Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 526: Test #36 Audit and Update Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2
Table 527: Test #255 Signaling Link State Check Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
0
ABRT
1018
ABRT
Maintenance is disabled on this trunk.
1. Enable maintenance by entering y in the Maintenance Tests field on 
the change trunk-group form.
1114
ABRT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2