Avaya 03-300430 User Manual

Page of 2574
MAINT (PN’s Maintenance Circuit Pack)
Issue 1 June 2005
1495
 
Table 536: Test #106 Sanity Handshake Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to cabinet query was not received in the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2033
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2046
ABRT
The PN’s Maintenance circuit pack reported an invalid cabinet type. Not 
knowing the cabinet type of the PN will prevent all PN environment 
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the PN’s 
Maintenance circuit pack is defective, or the PN cabinet’s wiring is 
defective. First, replace the Maintenance circuit pack.
3. If the test continues to abort with 2046, then the PN cabinet’s wiring 
is defective in the A carrier, and the PN’s Maintenance circuit pack 
cannot read the backplane pins to determine the cabinet type.
10601
ABRT
Test disabled via software patch.
 1 of 2