Table 536: Test #106 Sanity Handshake Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to cabinet query was not received in the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2033
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2046
ABRT
The PN’s Maintenance circuit pack reported an invalid cabinet type. Not
knowing the cabinet type of the PN will prevent all PN environment
maintenance from running.
knowing the cabinet type of the PN will prevent all PN environment
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the PN’s
Maintenance circuit pack is defective, or the PN cabinet’s wiring is
defective. First, replace the Maintenance circuit pack.
defective. First, replace the Maintenance circuit pack.
3. If the test continues to abort with 2046, then the PN cabinet’s wiring
is defective in the A carrier, and the PN’s Maintenance circuit pack
cannot read the backplane pins to determine the cabinet type.
cannot read the backplane pins to determine the cabinet type.
10601
ABRT
Test disabled via software patch.