Avaya 03-300430 User Manual

Page of 2574
MAINT (PN’s Maintenance Circuit Pack)
Issue 1 June 2005
1501
 
PN Maintenance Circuit Pack Reset Test (#306)
This test is destructive.
The terminal connection will be dropped and, if the Emergency Transfer switch is in the AUTO 
position, Emergency Transfer will be disabled for the duration of the test.
The PN’s Maintenance circuit pack is reset by the active Expansion Interface circuit pack. After 
the Expansion Interface circuit pack reports that the PN’s Maintenance circuit pack has reset, a 
handshake message is sent to the Maintenance circuit pack. If the Maintenance circuit pack 
responds to the handshake, the test passes. If not, it fails. If the test passes, the PN-connected 
terminal is brought back up, and Emergency Transfer is restored to its previous state.
2033
ABRT
Response to the test was not received within the allowable time period.
1.  Retry the command at 1-minute intervals up to 5 times.
FAIL
The Sanity Maze of the PN’s Maintenance circuit pack is defective.
1. Replace the PN’s Maintenance circuit pack.
PASS
The Sanity Maze is working properly, and the PN’s Maintenance circuit 
pack can access the unused register. If recycle carrier (for PN 
carriers) does not work, the following problems may still exist:
1. The Carrier Port Power Unit or wiring to the Carrier Port Power Unit 
may be defective. See 
2. Since this test only tests the PN, there is a very small probability 
that the PN’s Maintenance circuit pack cannot access those 
registers that deal with PN devices. The Maintenance circuit pack 
may need to be replaced.
Table 539: Test #303 PN’s Maintenance Circuit Pack Sanity Maze Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2
Table 540: Test #306 PN Maintenance Circuit Pack Reset Test 
Error
Code
Test
Result
Description / Recommendation
1000
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 4