Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1508 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
MAPD-BD (MAPD Interface Circuit Pack TN802)
S8700 | 8710
 / 
S8500
The TN802 Multiple Application Platform (MAP-D) circuit pack allows sending voice and fax 
from a Communication Manager media server through the Internet to another Communication 
Manager media server also having this feature or to other PBXs that are equipped with the 
Internet Telephony server (ITS-E).
Throughout this section, the term TN802 means the MAP-D IP trunk circuit pack.
Be sure to observe these special considerations for the TN802:
Port alarms on this circuit pack display as “TIE-DS1” in the Alarm and Error logs.
The reset board command reboots the MAPD PC CPU, but busyout board only 
busies out every emulated port on the board.
Switch resets that take the switch out of service for more than 20 seconds also cause the 
MAPD's PC to reboot, which takes several minutes to complete.
Switch-Demanded Tests
Switch-demanded diagnostic tests on the TN802 do not run unless the Internet trunking 
application is running on Windows NT, located on the circuit pack.
Feature Limitations
The Internet trunking application relies on the single call scenario, or a direct, point-to-point call 
that does not terminate at multiple S8700 Media Server nodes through call processing. 
MO Name in 
Alarm Log
Alarm
Level
Initial SAT Command to Run
Full Name of MO
MAPD-BD
MAJ
test board location sh
MAPD Interface circuit pack
MAPD-BD
MIN
test board location l
MAPD Interface circuit pack
MAPD-BD
WRN
test board location sh
MAPD Interface circuit pack