Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1522 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
5.
Replace the circuit pack.
Slide the circuit pack into the slot, and lock the latching
lever.
6.
Wait for initialization.
Wait for:
●
the circuit pack to reseat (faceplate LEDs light go
out).
out).
●
Windows 2000 boots (PC BOOT appears on the
faceplate LCD).
faceplate LCD).
●
IP Trunk application to run (IP TRK # appears on
the faceplate LCD).
the faceplate LCD).
Table 549: Replacing the TN802 hard drive (continued)
Step
Description
Comments
2 of 2
Table 550: MAPD (TN802) Error Log entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
)
0
Any
Any
Any
test board location
)
0
Circuit pack removed or
SAKI (#53)
MIN
WRN
1
ON
0
busyout board
location
WRN
OFF
release board
location
0
WRN
OFF
add ds1 location
125 (
none 3
None
MIN
WRN
2
ON
257 (
65535
Control Channel Loop
(#52)
MIN
ON
test board location
l r 20
257 (
Any
None
513 (
Any
MIN
WRN
3
ON
1 of 3