Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1528 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
r. Error Type 3841: The circuit pack detected a transient hardware logic error (for example, 
program logic inconsistency). This error resolves when no faults are detected for 100 
minutes. The value in Aux Data field (4358) indicates the type of hardware problem.
s. Error Type 3842: Bad Translation RAM Location Found error. The call continues by using 
another translation location. This error is not service-affecting and requires no action.
t. Error Type 3843: LAN Receive Parity error. The circuit pack detected an error in a received 
frame from the packet bus. These errors are most likely caused by a packet-bus problem, 
but may be due to a circuit-pack fault.
1. Determine whether the problem is isolated to this circuit pack or the problem is caused by 
packet-bus faults (see 
u. Error Type 3999: The circuit pack sent a large number of control-channel messages to the 
switch within a short period of time.
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
Error Type 1538 
(hyperactivity) 
also present?
Then the system:
Y
Takes the circuit pack out-of-service due to hyperactivity.
N
Does not take the circuit pack out-of-service, but the circuit pack 
has generated 50% of the messages necessary to be considered 
hyperactive. This may be normal during heavy traffic periods.
 2 of 2