MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 June 2005
1529
 
Shutting Down NT on the TN802
Before removing the TN802 circuit pack from the carrier, shut Windows NT down first by 
following either procedure described in 
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Table 551: Windows NT shutdown procedures 
Step
Faceplate button
PC interface
1.
Push the recessed button on the front 
faceplate and hold it in.
Click on the Start button in the lower left 
corner.
2.
“M shut” flashes on the LCD display
Click on Shut Down.
3.
When shutdown is complete, “MSHUT 
#” displays (“#” is blinking).
Select the Shut down the computer? 
radio button.
4.
Remove the circuit pack.
Click on OK.
5.
Wait for the message indicating that 
shutdown is complete.
6.
Remove the circuit pack.
Order of Investigation
Apply to 
TN802?
1
Short Test 
Sequence
Long Test 
Sequence
Reset 
Board 
Sequence
D/ND
2
NPE Connection Audit test (#50)
Y
X
ND
Control Channel Loop test (#52)
Y
X
ND
Loss of Signal Alarm Inquiry test (#138)
N
X
X
ND
Blue Alarm Inquiry test (#139)
N
X
X
ND
 1 of 2