Avaya 03-300430 User Manual
MEDPRO (Media Processor MAPD Circuit Pack)
Issue 1 June 2005
1547
Ping Test (#1379)
This test is a nondestructive test. It runs because of in-line errors, during periodic and
scheduled maintenance, and on demand.
This test verifies that the MedPro circuit pack can communicate to other nodes on the LAN by
pinging the gateway IP address as defined on the IP Interfaces screen (display
ip-interface location).
If the PING is successful, this test looks at the PING round trip delay. If a round trip delay of
greater than 4 seconds is reported, a separate error is logged. Excessive round trip delays do
not take the MedPro out of service.
Services can execute the standard ping command using the C-LAN board address and
scheduled maintenance, and on demand.
This test verifies that the MedPro circuit pack can communicate to other nodes on the LAN by
pinging the gateway IP address as defined on the IP Interfaces screen (display
ip-interface location).
If the PING is successful, this test looks at the PING round trip delay. If a round trip delay of
greater than 4 seconds is reported, a separate error is logged. Excessive round trip delays do
not take the MedPro out of service.
Services can execute the standard ping command using the C-LAN board address and
MedPro IP address to see the actual round-trip delay.
Table 568: Test #1379 Ping Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
1
2
2
ABRT
Internal Error.
1. Retry the command at 1-minute intervals up to 3 times.
7
ABRT
Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
2. Repeat the test.
3. If the test still aborts, escalate the problem.
2000
ABRT
Response to the test was not received from the Media Processor circuit
pack within the allowable time period.
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack.
Reset the circuit pack by issuing busyout board location and
reset board location.
reset board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
The necessary system resources to execute the test could not be
allocated.
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
1 of 2