Avaya 03-300430 User Manual

Page of 2574
MEDPRO (Media Processor MAPD Circuit Pack)
Issue 1 June 2005
1547
 
Ping Test (#1379)
This test is a nondestructive test. It runs because of in-line errors, during periodic and 
scheduled maintenance, and on demand.
This test verifies that the MedPro circuit pack can communicate to other nodes on the LAN by 
pinging the gateway IP address as defined on the IP Interfaces screen (display 
ip-interface location
).
If the PING is successful, this test looks at the PING round trip delay. If a round trip delay of 
greater than 4 seconds is reported, a separate error is logged. Excessive round trip delays do 
not take the MedPro out of service.
Services can execute the standard ping command using the C-LAN board address and 
MedPro IP address to see the actual round-trip delay.
Table 568: Test #1379 Ping Test 
Error
Code
Test
Result
Description / Recommendation
1
2
ABRT
Internal Error.
1. Retry the command at 1-minute intervals up to 3 times.
7
ABRT
Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
2. Repeat the test.
3. If the test still aborts, escalate the problem.
2000
ABRT
Response to the test was not received from the Media Processor circuit 
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack. 
Reset the circuit pack by issuing busyout board location and 
reset board location.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
The necessary system resources to execute the test could not be 
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
 1 of 2