Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1548 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Windows 2000 Reset Test (#1381)
This test resets the circuit pack. The test is highly destructive and can be initiated only by a
system technician-demanded reset board location.
system technician-demanded reset board location.
2801
ABRT
No IP address defined.
1. Verify IP Interfaces translations and retest.
2802
ABRT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
2805
FAIL
The number of pings received did not match the number sent (normally
one ping sent). This means that no ping responses were received from
the gateway defined on the ip-interfaces screen for the Media
Processor.
one ping sent). This means that no ping responses were received from
the gateway defined on the ip-interfaces screen for the Media
Processor.
1. Retry the command at 1-minute intervals up to 3 times.
2807
ABRT
The board is administered, but not enabled in change
ipserver-interface.
7
89
1007
89
1007
FAIL
Ping to the destination failed through this port due to the destination
down.
down.
1. Verify that at least one destination reachable through this port is up.
2. Once verified, use test port location to verify that the H.323
Signaling Group Ping test (#1387) passes.
PASS
Ping through this port successful.
Table 568: Test #1379 Ping Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2
Table 569: Test #1381 NT Reset Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
None
ABRT
System resources required for this test are not available.
1. Retry reset board location at 1-minute intervals up to 5 times.
1 of 2