Avaya 03-300430 User Manual
MEDPRO (Media Processor MAPD Circuit Pack)
Issue 1 June 2005
1549
1015
ABRT
Port is not out-of-service.
1. Busyout the circuit pack (busyout board location).
2. Execute reset board location.
2. Execute reset board location.
2100
ABRT
System resources required for this test are not available.
1. Retry reset board location at 1-minute intervals up to 5 times.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute reset board location.
2. If the problem persists, replace the circuit pack.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
1. Run the short test sequence.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the
MEDPRO interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
down. Reseating the board re-initializes it.
3. If the board was found to be inserted correctly, enter busyout
board location.
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 569: Test #1381 NT Reset Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2