Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1568 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
System resources required to run this test are not available. The port 
may be busy with a valid call.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
The battery feed circuitry is tested for proper battery voltage by testing 
the switchhook state. In response to the test message, the on-board 
firmware terminates the line and checks for switch-hook presence. The 
termination is then removed, and a check is made for no switch-hook 
presence. The MET set must be on-hook for the test to execute.
1. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1018
ABRT
Test disabled by software patch.
2000
ABRT
This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. 
If this error type is present, then release the port using release 
station extension
 and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 579: Test #35 Port Diagnostic Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3