Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1572 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 581: Test #57 Hybrid Circuit and Conference Circuit Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port 
may be busy with a valid call.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1001
ABRT
System resources required to run this test were not available. This could 
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present or some 
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 
times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension 
of the port. Use status station to determine the service state of 
the port. If the port is in use, wait until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
 1 of 3